The Operating Frequency Percentage failed to reach 100%

Water Flow adjustment

 

Various factors may influence the operational frequency, including temperature settings, water flow, ambient temperature, and mode configurations.

 

Steps to take to resolve the issue:

  • Verify the temperature variance between the water inlet and outlet.
  • If the variance exceeds 3°C:

 

  1. For single-speed pumps: 
    Ensure there are no obstructions in the water flow and consider adjusting the water valve.

 

2. For variable-speed pumps: Increase pump speed to enhance water flow.

 

By elevating pressure and speed in the water flow, the temperature difference between the water inlet and outlet should decrease. This will increase the demand for heat, prompting the AI system to adjust the speed of your heat pump accordingly.